Assessment of portable chlorophyll meters for measuring crop leaf chlorophyll concentration

Simple item page

Simple item page

Full item details

creativework.keywords - en
leaf chlorophyll concentration
portable chlorphyll meter
sensitivity analysis
remote sensing
radiative transfer model
creativework.keywords - fr
concentration de chlorphylle dans les feuilles
compteur de chlorophylle portable
analyse de sensibilité
télédetection
modèle de transfer radiatif
dc.contributor.author
Dong, Taifeng
Shang, Jiali
Chen, Jing M.
Liu, Jiangui
Qian, Budong
Ma, Baoluo
Morrison, Malcolm J.
Zhang, Chao
Liu, Yupeng
Shi, Yichao
Pan, Hui
Zhou, Guisheng
dc.date.accessioned
2023-04-18T14:42:08Z
dc.date.available
2023-04-18T14:42:08Z
dc.date.issued
2019-11-19
dc.description - en
N/A
dc.description.abstract - en
Accurate measurement of leaf chlorophyll concentration (LChl) in the field using a portable chlorophyll meter (PCM) is crucial to support methodology development for mapping the spatiotemporal variability of crop nitrogen status using remote sensing. Several PCMs have been developed to measure LChl instantaneously and non-destructively in the field, however, their readings are relative quantities that need to be converted into actual LChl values using conversion functions. The aim of this study was to investigate the relationship between actual LChl and PCM readings obtained by three PCMs: SPAD-502, CCM-200, and Dualex-4. Field experiments were conducted in 2016 on four crops: corn (Zea mays L.), soybean (Glycine max L. Merr.), spring wheat (Triticum aestivum L.), and canola (Brassica napus L.), at the Central Experimental Farm of Agriculture and Agri-Food Canada in Ottawa, Ontario, Canada. To evaluate the impact of other factors (leaf internal structure, leaf pigments other than chlorophyll, and the heterogeneity of LChl distribution) on the conversion function, a global sensitivity analysis was conducted using the PROSPECT-D model to simulate PCM readings under different conditions. Results showed that Dualex-4 had a better performance for actual LChl measurement than SPAD-502 and CCM-200, using a general conversion function for all four crops tested. For SPAD-502 and CCM-200, the error in the readings increases with increasing LChl. The sensitivity analysis reveals that deviations from the calibration functions are more induced by non-uniform LChl distribution than leaf architectures. The readings of Dualex-4 can have a better ability to restrict these influences than those of the other two PCMs.
dc.identifier.citation
Dong, T., Shang, J., Chen, J. M., Liu, J., Qian, B., Ma, B., Morrison, M. J., Zhang, C., Liu, Y., Shi, Y., Pan, H., & Zhou, G. (2019). Assessment of Portable Chlorophyll Meters for Measuring Crop Leaf Chlorophyll Concentration. Remote Sensing, 11(22), 2706. https://doi.org/10.3390/rs11222706
dc.identifier.doi
https://doi.org/10.3390/rs11222706
dc.identifier.issn
2072-4292
dc.identifier.uri
https://open-science.canada.ca/handle/123456789/209
dc.language.iso
en
dc.publisher
MDPI
dc.rights.openaccesslevel - en
Gold
dc.rights.openaccesslevel - fr
Or
dc.subject - en
Agriculture
dc.subject - fr
Agriculture
dc.subject.en - en
Agriculture
dc.subject.fr - fr
Agriculture
dc.title - en
Assessment of portable chlorophyll meters for measuring crop leaf chlorophyll concentration
dc.title.fosrctranslation - fr
Assessment of portable chlorophyll meters for measuring crop leaf chlorophyll concentration
dc.type - en
Article
dc.type - fr
Article
local.article.journalissue
22
local.article.journaltitle
Remote Sensing
local.article.journalvolume
11
local.article.pagination
2706
local.peerreview - en
Yes
local.peerreview - fr
Oui
Download(s)

Original bundle

Now showing 1 - 1 of 1

Thumbnail image

Name: AssessmentPortableChlorophyllMeters_2019.pdf

Size: 2.19 MB

Format: PDF

Download file

Page details

Date modified: