Unbiased passive sampling of all polychlorinated biphenyls congeners from air

Simple item page

Simple item page

Full item details

dc.contributor.author
Li, Yuening
Zhan, Faqiang
Shunthirasingham, Chubashini
Lei, Ying
Hung, Hayley
Wania, Frank
dc.date.accepted
2023-06-26
dc.date.accessioned
2024-06-06T13:49:02Z
dc.date.available
2024-06-06T13:49:02Z
dc.date.issued
2023-06-29
dc.date.submitted
2023-04-24
dc.description.abstract - en
The desire to quantify the presence of a wide range of polychlorinated biphenyls (PCBs) in air is driven both by an interest in the sources and fate of unintentionally produced congeners and in quantifying human inhalation exposure to volatile PCBs. The wide volatility range can introduce bias when sampling the entire suite of PCBs. Here, we present the result of a field calibration experiment that demonstrates that even the most volatile PCBs maintain linear uptake in a passive air sampler using XAD-resin as the sorbent (XAD-PAS). Empirically derived sampling rates (SRs) for 66 congeners decrease with the number of chlorines and, within a homologue, increase with the number of chlorines in the ortho-position. The large seasonal temperature range at the site of the calibration allowed for an estimation of the temperature dependence of the SRs. The effects of chlorine substitution and temperature can be expressed quantitatively through a regression relating the SR to the sorption constant to XAD from the gas phase. As a result, it is possible to estimate SRs for all congeners at any deployment temperature. The XAD-PAS is well suited for unbiased sampling of gaseous PCBs in a wide variety of settings.
dc.description.abstract-fosrctranslation - fr
La volonté de quantifier la présence d’une large gamme de polychlorobiphényles (PCB) dans l’air est motivée à la fois par un intérêt pour les sources et le devenir des congénères produits involontairement, et par la quantification de l’exposition humaine par inhalation aux PCB volatils. La large plage de volatilité peut introduire un biais lors de l’échantillonnage de l’ensemble des PCB. Nous présentons ici les résultats d’une expérience d’étalonnage sur le terrain qui démontre que même les PCB les plus volatils conservent une absorption linéaire dans un échantillonneur d’air passif utilisant la résine XAD comme sorbant (XAD-PAS). Les taux d’échantillonnage empiriques pour 66 congénères diminuent avec le nombre de chlores et, à l’intérieur d’un homologue, augmentent avec le nombre de chlores en position orthogonale. La grande amplitude thermique saisonnière sur le site de l’étalonnage a permis d’estimer la dépendance des taux d’échantillonnage par rapport à la température. Les effets de la substitution du chlore et de la température peuvent être exprimés quantitativement par une régression reliant le taux d’échantillonnage à la constante de sorption du XAD à partir de la phase gazeuse. Il est donc possible d’estimer les taux d’échantillonnage pour tous les congénères à n’importe quelle température de déploiement. Le XAD-PAS est bien adapté à l’échantillonnage non biaisé des PCB gazeux dans une grande variété de contextes.
dc.description.fosrcfull - en
This document is the unedited Author’s version of a Submitted Work that was subsequently accepted for publication in [Journal Title], copyright © [include copyright notice from the published article] after peer review. To access the final edited and published work see <a href="https://doi.org/10.1021/acs.estlett.3c00271">https://doi.org/10.1021/acs.estlett.3c00271</a>.
dc.description.fosrcfull-fosrctranslation - fr
Ce document est la version non éditée d'un travail soumis par l'auteur qui a été accepté pour publication dans [titre], droit d'auteur © [l'avis de droit d'auteur] après évaluation par les pairs. Pour accéder au travail final édité et publié, voir <a href="https://doi.org/10.1021/acs.estlett.3c00271">https://doi.org/10.1021/acs.estlett.3c00271</a>.
dc.identifier.issn
2328-8930
dc.identifier.uri
https://open-science.canada.ca/handle/123456789/2545
dc.language.iso
en
dc.publisher
American Chemical Society
dc.relation.isreplacedby
https://doi.org/10.1021/acs.estlett.3c00271
dc.rights - en
Open Government Licence - Canada
dc.rights - fr
Licence du gouvernement ouvert - Canada
dc.rights.openaccesslevel - en
Green
dc.rights.openaccesslevel - fr
Vert
dc.rights.uri - en
https://open.canada.ca/en/open-government-licence-canada
dc.rights.uri - fr
https://ouvert.canada.ca/fr/licence-du-gouvernement-ouvert-canada
dc.subject - en
Nature and environment
Science and technology
dc.subject - fr
Nature et environnement
Sciences et technologie
dc.subject.en - en
Nature and environment
Science and technology
dc.subject.fr - fr
Nature et environnement
Sciences et technologie
dc.title - en
Unbiased passive sampling of all polychlorinated biphenyls congeners from air
dc.type - en
Submitted manuscript
dc.type - fr
Manuscrit soumis
local.article.journalissue
7
local.article.journaltitle
Environmental Science & Technology Letters
local.article.journalvolume
10
local.pagination
17 pages, annex
local.peerreview - en
No
local.peerreview - fr
Non
Download(s)

Original bundle

Now showing 1 - 1 of 1

Thumbnail image

Name: UnbiasedPassiveSamplingAllPolychlorinatedBiphenylsCongenersAir.pdf

Size: 5.6 MB

Format: PDF

Download file

Collection(s)

Page details

Date modified: